TM 10-7360-204-13&P
2-15. OPERATION IN SALT WATER AREAS.
a. Keep equipment free of contact with salt water whenever possible. If contact is made, or if equipment is exposed to
salt spray, wash equipment frequently with clean fresh water.
b. Coat exposed surfaces of the range cabinet and burner assembly with corrosion preventive compound, P-14, (item
1, Table F-l).
2-16. OPERATION IN HIGH ALTITUDES.
Inspect the air pressure gage at more frequent intervals. Adjust the air control shutter as needed to compensate for air
pressure changes.
2-26