TM 10-7360-201-10
2-10.
SHUTTING DOWN EQUIPMENT - Continued
a.
Mixing and Makeup Machinery.
(1)
(2)
b.
Oven.
WARNING
After oven burner is shut off let the blower run several
minutes after burner stops firing to clear out gas fumes.
(1)
Set fuel metering float valve adjusting screw (1) at position 0 and turn stop screw knob (3) clockwise to OFF
position.
(2)
Turn off bypass valve (4) if it has been used to bypass magnetic valve (5).
(3)
Close fuel tank shutoff gate valve (6).
(4)
Let blower run several minutes after burner stops firing to clear out gas fumes.
(5)
Push oven burner toggle switch (7) to OFF position.
6)
Push oven light toggle switch (8) to OFF position.
(7)
Push oven motor manual starter switch (9) to OFF position. For model M533 bakery oven, press stop button to
stop oven blower motor.
(8)
(9)
c.
Proofing Cabinet.
(1)
(2)
d.
Flour Sifter.
(1)
(2)
Burn reject bag to destroy weevils sifted from flour.
(3)
e.
(1)
Push in the main switch OFF.
(2)
Allow engine to idle for a few minutes to cool it.
(3)
Turn magneto switch to OFF position to stop engine.
(4)
Be sure all switches are in OFF position.
(5)
(6)
Perform after-operation (a) services listed in TM5-6115-321-12 for the generator set.
2-53