TM 10-7310-282-10
0027 00
Table 4. Ice Machine Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. No Power
Step 1. Check indicator panel.
Indicator panel should be lit.
Step 2. Check that all external
Establish or reestablish power
power connections have been
connections. Consult with
made.
facilities electricians if necessary.
If condition persists, notify unit
maintenance.
Valve should be on.
2. No Water
Step 1. Check water manifold
shutoff valve. Refer to TM 10-
5419-206-13 (Operator, Unit, and
Direct Support Maintenance for
Force Provider).
Step 2. Ensure water line is not
Remove, thaw, and reinstall a
frozen or otherwise obstructed or
frozen water line.
kinked.
Remove obstructions or kinks
from water lines.
If condition persists, notify unit
maintenance.
3. Does Not Produce
Step 1. Monitor harvest cycle.
Ice maker should produce a
Enough Ice
complete harvest in
approximately 20 minutes. If not,
notify unit maintenance.
Step 2. Ensure that there is
Clear obstructions from ice maker
sufficient airflow around ice
cabinet, and relocate ice maker if
maker.
necessary.
Relocate ice maker to ECU
discharge vent.
Step 3. Check bin door for fit or
Notify unit maintenance. Use
damage.
approved field expedient closure
Step 4. Check fit of ice maker to
Reinstall ice maker onto bin.
bin.
Step 5. Monitor volume of ice
More ice will be used in hot
used.
climates. Ensure that all
available ice makers are in
operation.
If condition persists, notify unit
maintenance.
4. Water in Bin
Check bin drain.
Remove all ice from bin. Clear
drain mechanically or chemically
(with bleach solution) from bin to
drain. Clean and sanitize bin,
and operate normally.
If condition persists, notify unit
maintenance.
0027 00-5