Table 1. Food Warming Cabinet Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. No Power
Step 1. Check settings at control
Mode selector should be set to
panel.
ON or HUMIDITY
Step 2. Check that all external
Establish or reestablish power
power connections have been
connections. Consult with
made.
facilities electricians if necessary.
If condition persists, notify unit
maintenance.
2. Cabinet Loses Heat
Step 1. Check settings at control
Mode selector should be set to
panel.
ON or HUMIDITY.
Thermostat or humidity control
should be set to highest setting.
Step 2. Check that all external
Establish or reestablish power
power connections have been
connections. Consult with
made.
facilities electricians if necessary.
Step 3. Inspect door gasket
Notify unit maintenance.
condition.
Step 4. Inspect door fit when
Notify unit maintenance.
closed.
If condition persists, notify unit
maintenance.
0027 00-2