TM 10-7310-282-10
0027 00
Table 11. Reach-in Refrigerator Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Does Not Cool
Step 1. Check power cord
Connect power cord.
connection.
Step 2. Check door fit and
Adjust misaligned door.
condition of door gasket.
If condition persists, notify unit
maintenance.
2. Excessive Running
Check door fit and condition of
Adjust misaligned door.
door gasket.
If condition persists, notify unit
maintenance.
3. Water In Cabinet
Check door fit and condition of
Adjust misaligned door.
door gasket.
If condition persists, notify unit
maintenance.
0027 00-12