TM 10-7310-282-10
0027 00
Table 14. Single Coffee Urn Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. No Power
Step 1. Check thermostat
Thermostat should be at BREW
setting.
or HIGH position.
Step 2. Check ON/OFF switch (if
Switch should be ON.
fitted).
Step 3. Check circuit breaker.
Reset circuit breaker.
Step 4. Check power cord
Reconnect power cord.
connection.
If condition persists, notify unit
maintenance.
2. Does Not Brew
Step 1. Check brew indicator
Press START / BREW button to
lights.
intiiate brew cycle - indicator is
not lit.
Step 2.
Check ON/OFF switch (if
Switch should be ON.
fitted).
Step 3.
Check thermostat
Thermostat should be at BREW
setting.
or HIGH position.
Step 4.
Check circuit breaker.
Reset circuit breaker.
Step 5.
Check water level.
Add water.
If condition persists, notify unit
maintenance.
3. Coffee Weak
Step 1. Check thermostat
Thermostat should be at BREW
setting.
or HIGH position.
Step 2. Check batch switch
If making a half batch, switch
should be set on HALF.
Step 3. Check water
Allow at least 45 minutes for
temperature.
jacket water to heat.
Step 4. Check coffee grounds.
Make sure that the correct
measure of grounds have been
placed in the filter.
If condition persists, notify unit
maintenance.
0027 00-15/(16 Blank)