TM 10-7360-206-13
0038 00
REPAIR MOUNTED CAN OPENER
(APPLIES TO P/N A-A-52206, TYPE IV, GR. B, CAGEC 81337, NSN 7330-01-411-9788 ONLY)
BLADE
Replace
To remove the blade, remove the thumbscrew (1), and pull pin (2). Pull the knife holder (3) forward and
out from the main body (4) of the can opener. Remove the blade (5).
Install a new blade (5) behind the knife holder (3) and install the knife holder into the main body (4) of the
can opener.
Replace the pull pin (2) and install the thumb screw (1). Tighten securely.
4
3
2
1
5
END OF WORK PACKAGE